banner

Blog

Jun 30, 2023

Assessing physical abilities of sarcopenia patients using gait analysis and smart insole for development of digital biomarker

Scientific Reports volume 13, Article number: 10602 (2023) Cite this article

485 Accesses

1 Altmetric

Metrics details

The aim of this study is to compare variable importance across multiple measurement tools, and to use smart insole and artificial intelligence (AI) gait analysis to create variables that can evaluate the physical abilities of sarcopenia patients. By analyzing and comparing sarcopenia patients with non sarcopenia patients, this study aims to develop predictive and classification models for sarcopenia and discover digital biomarkers. The researchers used smart insole equipment to collect plantar pressure data from 83 patients, and a smart phone to collect video data for pose estimation. A Mann–Whitney U was conducted to compare the sarcopenia group of 23 patients and the control group of 60 patients. Smart insole and pose estimation were used to compare the physical abilities of sarcopenia patients with a control group. Analysis of joint point variables showed significant differences in 12 out of 15 variables, but not in knee mean, ankle range, and hip range. These findings suggest that digital biomarkers can be used to differentiate sarcopenia patients from the normal population with improved accuracy. This study compared musculoskeletal disorder patients to sarcopenia patients using smart insole and pose estimation. Multiple measurement methods are important for accurate sarcopenia diagnosis and digital technology has potential for improving diagnosis and treatment.

Sarcopenia is an age-related decrease in muscle mass, strength, and function. It is a common problem among older people and can lead to reduced mobility, increased risk of falls, fractures and reduced quality of life1. The causes of sarcopenia are complex, including hormonal changes, reduced physical activity, oxidative stress and inflammation, and changes in muscle protein synthesis and breakdown2,3. Several guidelines have been developed to diagnose sarcopenia, and there are representative guidelines presented by institutions such as EWGSOP and AWGS4,5,6. These diagnostic guidelines include physical function evaluation items for patients with sarcopenia, which are currently being measured in various ways1,7,8.

Diagnosing sarcopenia involves assessing muscle mass, strength, physical performance, and body composition through various methods. A recent focus has been on evaluating physical performance, with tools like the Gait Speed Test, Chair Stand Test, Timed Up and Go (TUG) Test, and Handgrip Strength Test being commonly used9,10. However, these methods are susceptible to subjective bias from the measurer or the environment. To address this, there has been a push towards using artificial intelligence (AI) to gather physical performance data11. In particular, studies such as calculating joint angles and ranges using pose estimation are being actively discussed12,13.

Research is underway to enhance the measurement accuracy of patients' physical performance using smart equipment, alongside AI technologies such as body pose estimation14,15,16. Pose estimation is a computer vision technology that uses deep learning models to estimate human body key points in real-time. It tracks and detects human body joints and parts, allowing for 2D or 3D pose estimation17,18,19. Currently, there is active research being conducted to compare its accuracy and usefulness with VICON motion system (Vicon Nexus; Vicon Motion Systems Ltd., Oxford, England), which uses multiple cameras to perform highly accurate 3D motion capture12,20. Through these comparative studies, the accuracy and usefulness of the pose estimation method is being verified12,20,21. In addition, various wearable devices such as smartwatches and smart insoles are currently being used to measure patients' physical performance. In particular, research utilizing Inertial Measurement Unit (IMU) sensors such as the Smart Insole is actively being conducted in the field of muscular dystrophy, and significant spatial and temporal parameters are being identified. As an example, there have been studies analyzing the gait of osteoporosis and muscular dystrophy using AI and wearable sensors. There have also been studies identifying patients with muscular dystrophy using IMU sensors22,23.

In current research on various musculoskeletal patients, including sarcopenia, it is common to use a single measurement tool for analysis. However, this approach may not fully capture the diversity of variables that each tool can measure, and may not accurately reflect the relative importance of variables when comparing across tools. Therefore, to develop predictive and classification models for sarcopenia and discover digital biomarkers, it is crucial to compare variable importance across multiple measurement tools and find a simple, accurate assessment tool. The purpose of this study is to use smart insole and AI gait analysis together to create variables that can evaluate the physical abilities of sarcopenia patients, before expanding to predictive and classification models, and to compare and analyze sarcopenia patients with healthy individuals.

In order to collect insole and pose esimation data for sarcopenia, GNUH (Gyeongsang National University Hospital, Jinju, South Korea) conducted a study on 83 patients with musculoskeletal disorders in 2022. Of the 83 patients with musculoskeletal disorders, 23 were pre-judged to have sarcopenia. Among the 23 sarcopenia patients, there were 15 females and 8 males, while the Control group consisted of 23 and 31 individuals, respectively (refer to Supplementary Table S1). The study adhered to the principles of the Declaration of Helsinki and was approved by the IRB at Gyeongsang National University Hospital. All research procedures were carried out with strict adherence to ethical standards, including protection of participants' privacy, confidentiality, and rights.

To collect data from the insoles of 83 patients, we used the Smart Insole equipment from SALTED (Seoul, South Korea), which is equipped with four pressure sensors and three-axis IMU sensors for each insole, as shown in Fig. 124. The insoles wirelessly transmitted four-channel foot pressure and three-channel acceleration data at a sampling rate of 30 Hz. To collect plantar pressure data, each patient wore the insoles and walked for one minute16. A smart phone (Galaxy A20, Samsung Electronics) equipment was used to collect video data to be used for pose estimation. The measurement was conducted using the rear camera of a smartphone, and the recorded video had a resolution of 1080p and a frame rate of 30fps. As for the video recording protocol, as shown in Fig. 2, a lateral walking video was recorded once for a walking distance of 5 m. In addition, the distance between the patient and the camera was based on a vertical distance of 2 m and a height of 1.3 m from the floor. There are no standardized measurement distances and heights. For this study, a measurement distance of 5 m was used and the minimum distance of 2 m was set to fit the entire screen. For the height from the ground, we used approximately 1.3, the height of a person's shoulders, for angle and horizontal correction.

Smart Insole for gait analysis.

Video recording protocol.

We used the SALTED Smart Insole (Seoul, South Korea) equipment to collect plantar pressure data from 83 patients. The insoles, as shown in Fig. 1, were equipped with four pressure sensors and one three-axis IMU sensor for calibration purposes. Each patient wore the insoles while walking for one minute, and the pressure data were collected using the four pressure sensors. The SALTED internal program was then utilized to calculate relevant variables as shown in Fig. 3.

Gait cycle captured by smart inasole.

To estimate and analyze the patient's pose, we employed video analysis for pose estimation using the Dr.log application and the DMS system (Deevo, Jinju, Korea)25,26. The Dr.log application collected patients' gait videos in real-time and stored them in a database. The DMS system performed real-time pose estimation from the collected database. For the pose estimation process, we utilized Mediapipe, an open-source software developed by Google that uses a Convolutional Neural Network (CNN) model based on neural network-based deep learning algorithms. The CNN model includes a convolutional layer and a pooling layer to extract features from the input image, followed by fully connected and softmax layers. Using Mediapipe's pose estimation function, we estimated a total of 33 key points, with 25 representing the upper body and 8 representing the lower body, utilizing the Blaze Pose model, as shown in Fig. 427.

Visualization of Blaze Pose’s 33 key points in human pose estimation.

We utilized R Studio, a statistical analysis program, to analyze the centrality and variability of all collected patient data. In addition, due to the small sample size, we conducted Shapiro normality tests and used Mann–Whitney U tests when normality assumptions were not met. We compared the sarcopenia group and control group using R Studio and created image visualizations for each group's results. The significance level was set at *p < 0.1, **p < 0.01, and ***p < 0.001.

The study adhered to the principles of the Declaration of Helsinki and was approved by the IRB at Gyeongsang National University Hospital. (IRB No. GNUH 2022-01-032-008) All research procedures were carried out with strict adherence to ethical standards, including protection of participants’ privacy, confidentiality, and rights.

We conducted a normality test on each variable in both the sarcopenia group (n = 23) and control group (n = 60). The test indicated that the majority of variables in the sarcopenia group did not adhere to the normality assumption (refer to Supplementary Table S2). Therefore, we compared the variables between the two groups using the Mann–Whitney U test. The measurement values are presented in Tables 1 and 2, and the p-values for each variable are shown at the bottom of each table. Table 1 presents the characteristics of the two groups using smart insole, while Table 2 presents the characteristics using pose estimation method (refer to Supplementary Figs. S1 and S2). The smart insole provides a total of 6 variables (Total number of steps, Cadence, R double support, R single support, L double support, L single support) and similarly, the pose estimation provides results for 23 variables representing each joint point. The p-values are provided for all 6 variables in the case of the smart insole, and only for 15 variables excluding the maximum and minimum values in the case of pose estimation. The description of the 23 variables provided by pose estimation is presented in Supplementary Table S3. In order to assess the detection accuracy of pose estimation using Mediapipe, key points representing the head, shoulders, elbows, wrists, hips, knees, and ankles were utilized as reference points. The detection criterion was based on cases where the marker positions were flipped or estimation was not performed. A total of 100 images were evaluated for this purpose. The accuracy was determined by considering whether the estimation was successful for each of the 15 keypoints. The resulting detection accuracy for the 15 keypoints was measured at 89.23%.

The characteristics of the Sarcopenia and Control groups were investigated using smart insole technology, and the results are summarized in Table 1. The Sarcopenia group had a mean total number of steps of 84.32 steps and a cadence of 87.42 steps/min. For the R double support, R single support, L double support, and L single support means, the values were 17.44%, 36.30%, 17.00%, and 36.97%, respectively. In comparison, the Control group had a mean total number of steps of 88.32 steps and a cadence of 88.04 steps/min. The means for R double support, R single support, L double support, and L single support were 17.08%, 36.74%, 17.22%, and 37.22%, respectively. The Mann–Whitney U test revealed no significant differences between the two groups for any of the variables. However, caution should be taken when interpreting the results, as the high p-values for the total number of steps, cadence, R double support, R single support, L double support, and L single support suggest that small sample sizes may have influenced the findings.

The Dr.log site was used to extract joint point data from the image through pose estimation, and Dr.log DMS was then employed to identify time series patterns and characteristic values for coordinate information. The Mann–Whitney U test results classified the 15 variables studied into three groups based on their p-values. The first group, including knee mean (p = 0.433), ankle range (p = 0.252), and hip range (p = 0.294), had p-values greater than 0.1, indicating that these variables did not exhibit a significant difference between the two groups. The second group, consisting of hip mean, shoulder angle range, ankle mean, all max dif, hipankle dif, kneeankle dif, knee dif, ankle dif, and hip dif, had p-values less than 0.001, demonstrating a significant difference between the two groups. The third group, composed of hipknee dif and shoulder angle mean, had p-values of 0.003 and 0.002, respectively, indicating that they also displayed a significant difference between the two groups, although to a lesser extent than the second group. In summary, the results suggest that using pose estimation reveals a significant difference in joint angle measurements between the two groups, which could be useful in understanding the fundamental cause of movement pattern differences between them.

There are different approaches to measure gait, with smart insoles and pose estimation being two commonly used methods. Smart insole is a device that can be inserted into a shoe to measure various parameters of the foot during gait, such as pressure distribution, force, and acceleration28,29. The device contains sensors that collect data, which is then sent to a computer for analysis. The benefits of using smart insoles include detailed information about the foot's biomechanics, ease of use, non-invasiveness, and no need for special setup29,30. In contrast, pose estimation is a computer vision technique that uses a camera to track joint movement in the body15,31. By recording a person's movements as they walk or run, the software can estimate the position of joints in the body. The advantage of pose estimation is that it provides a comprehensive view of the entire body, including the limbs, spine, and pelvis, making it easier to study external variables such as gait asymmetry32. However, it can be more challenging to set up and requires more technical expertise.

There were significant differences between the two methods in this study. Smart insole primarily focuses on the foot, providing detailed information on foot biomechanics33. Specifically, there are areas that pose estimation fails to detect, such as ground reaction forces on both feet, and it has advantages in calculating variables like single support and double support. It is more practical to use in clinical settings, as space limitations do not occur. However, smart insole may not provide a complete picture of the body's movement during gait, leading to large deviations in the measured variables. Furthermore, in musculoskeletal patients, it is crucial to verify whether consistent time series patterns are present even when sufficient foot pressure is not applied. Pose estimation provides a more comprehensive view of the entire body, detecting asymmetries and compensations in gait18,31,32. The study showed significant differences in most variables using pose estimation, particularly the angle of maximum opening in the shoulder, ankle, and stationary posture. However, there was also a limitation that measuring with pose estimation required sufficient space and proper filming location.

Patients with sarcopenia exhibit gait changes due to the progressive decline in skeletal muscle mass, strength, and function. These changes are characterized by decreased single support time and increased double support time, primarily resulting from reduced muscle strength and impaired balance34,35. However, in our study, the smart insole was unable to fully capture these distinctive gait characteristics. In contrast, pose estimation accurately represented the gait cycle characteristics, as demonstrated in Tables 1 and 2. Specifically, the smart insole showed difficulty in identifying significant differences between the elderly patient group and the control group of relatively young and healthy individuals. On the other hand, pose estimation offered the advantage of estimating markers that could capture a wider range of functional variables. Compared to smart insole, pose estimation allowed for the consideration of a greater number of biomarkers related to various body functions. Therefore, using pose estimation for comparing the sarcopenia group with the non-sarcopenia group provided a broader perspective in assessing gait characteristics.

Research on sarcopenia is a rapidly evolving field, with ongoing efforts to identify digital biomarkers using various approaches. While previous studies have focused on using a single measurement device to identify biomarkers, it is becoming increasingly clear that a more comprehensive approach is needed. This requires the integration of multiple devices and variables to account for the complex nature of the disease. Therefore, further research is needed to combine the variables from existing smart insole and pose estimation studies to develop a predictive model and identify novel digital biomarkers.

When conducting pose estimation for muscle function evaluation in sarcopenia, the following limitations exist: (1) Pose detection accuracy: lighting, camera angle, and clothing can limit the accuracy of pose estimation for sarcopenia diagnosis; (2) Environmental constraints: environmental factors such as background clutter and movement can hinder pose estimation's ability to assess muscle function. Similarly, with the case of smart insoles, the following limitations exist: (1) Inaccuracy of sensors: The accuracy of smart insole’s IMU sensors can be affected due to the limitation of having only one IMU sensor for calibration purposes. Sensor drift, which refers to the gradual deviation of the sensor readings over time, can occur and cause inaccuracies in the collected data, which can affect the accuracy of the plantar pressure data results.; (2) Environmental constraints: Environmental conditions like uneven or slippery surfaces can impact the ability of smart insoles to evaluate muscle function.

Additionally, both methods have the following common limitations: (1) User dependence: the results of muscle function evaluation using smart insoles and pose estimation can be affected by factors such as correct wearing of insoles and the patient's physical characteristics; (2) Limitations in capturing physical parameters: using smart insoles and pose estimation for muscle function evaluation can result in inaccuracies if all the important physical parameters like muscle tension and adjustment are not included; (3) Lack of standardized protocol: concerns about the reliability of results can arise due to the absence of a standardized protocol for the use of smart insoles in muscle function evaluation and the absence of standardized camera equipment and shooting method protocols in the case of pose estimation.

Lastly, in this study, a comparison was conducted between 23 sarcopenic patients and 60 individuals without sarcopenia. During the process of comparing the groups, characteristics such as gender and age were not matched due to the limitation of a small sample size. To address this, the analysis results of the groups with matched characteristics are provided in Supplementary Table S4. In this case, when comparing the results with the original analysis in Tables 1 and 2, no significant differences in variables were observed.

In this study, a control group of 60 individuals with musculoskeletal disorders was compared to a group of 23 individuals with sarcopenia using both smart insole and pose estimation. The results indicated that the smart insole did not show any significant differences between the two groups, whereas the pose estimation variables showed significant differences in 12 out of 15 variables. These findings highlight the importance of using multiple measurement methods to develop accurate models for predicting and classifying sarcopenia. With the recent advancements in measurement technology, the accuracy of sarcopenia diagnosis has improved, and it is expected that more digital biomarkers will be discovered and utilized in future treatments. This underscores the potential of utilizing digital technology to improve the diagnosis and treatment of musculoskeletal disorders and sarcopenia.

The data used in this study were collected at Gyeongsang National University Hospital, and inquiries about the data should be directed to the author J.I.Y.

Santilli, V., Bernetti, A., Mangone, M. & Paoloni, M. Clinical definition of sarcopenia. Clin. Cases Miner. Bone Metab. 11, 177–180 (2014).

PubMed PubMed Central Google Scholar

Meng, S.-J. & Yu, L.-J. Oxidative stress, molecular inflammation and sarcopenia. Int. J. Mol. Sci. 11, 1509–1526 (2010).

Article CAS PubMed PubMed Central Google Scholar

Rom, O., Kaisari, S., Aizenbud, D. & Reznick, A. Z. Lifestyle and sarcopenia—Etiology, prevention, and treatment. Rambam Maimonides Med. J. 3, e0024 (2012).

Article PubMed PubMed Central Google Scholar

Cruz-Jentoft, A. J. et al. Sarcopenia: Revised European consensus on definition and diagnosis. Age Ageing 48, 16–31 (2019).

Article PubMed Google Scholar

Lim, W. S. et al. Singapore clinical practice guidelines for sarcopenia: Screening, diagnosis, management and prevention. J. Frailty Aging 11, 348–369 (2022).

CAS PubMed Google Scholar

Chen, L.-K. et al. 2019 Consensus update on sarcopenia diagnosis and treatment. J. Am. Med. Dir. Assoc. 21, 300-307.e2 (2020).

Article PubMed Google Scholar

Saeki, C. et al. Comparative assessment of sarcopenia using the JSH, AWGS, and EWGSOP2 criteria and the relationship between sarcopenia, osteoporosis, and osteosarcopenia in patients with liver cirrhosis. BMC Musculoskelet. Disord. 20, 615 (2019).

Article CAS PubMed PubMed Central Google Scholar

Stuck, A. K. et al. Predictive validity of current sarcopenia definitions (EWGSOP2, SDOC, and AWGS2) for clinical outcomes: A scoping review. J. Cachexia Sarcopenia Muscle https://doi.org/10.1002/jcsm.13161 (2022).

Article PubMed PubMed Central Google Scholar

Yee, X. S. et al. Performance on sit-to-stand tests in relation to measures of functional fitness and sarcopenia diagnosis in community-dwelling older adults. Eur. Rev. Aging Phys. Act. 18, 1 (2021).

Article PubMed PubMed Central Google Scholar

Coelho-Junior, H. J. et al. The physical capabilities underlying timed “Up and Go” test are time-dependent in community-dwelling older women. Exp. Gerontol. 104, 138–146 (2018).

Article PubMed Google Scholar

Gu, S. et al. Detection of sarcopenia using deep learning-based artificial intelligence body part measure system (AIBMS). Front. Physiol. 14, 1092352 (2023).

Article PubMed PubMed Central Google Scholar

Ota, M. et al. Verification of reliability and validity of motion analysis systems during bilateral squat using human pose tracking algorithm. Gait Posture 80, 62–67 (2020).

Article PubMed Google Scholar

Nakano, N. et al. Evaluation of 3D markerless motion capture accuracy using openpose with multiple video cameras. Front. Sports Act. Living https://doi.org/10.3389/fspor.2020.00050 (2020).

Article PubMed PubMed Central Google Scholar

Johnson, K. B. et al. Precision medicine, AI, and the future of personalized health care. Clin. Transl. Sci. 14, 86–93 (2021).

Article PubMed Google Scholar

Stenum, J. et al. Applications of pose estimation in human health and performance across the lifespan. Sensors 21, 7315 (2021).

Article ADS PubMed PubMed Central Google Scholar

Kim, J., Kang, S. & Kim, S.-J. A smart insole system capable of identifying proper heel raise posture for chronic ankle instability rehabilitation. Sci. Rep. 12, 10796 (2022).

Article ADS CAS PubMed PubMed Central Google Scholar

Güler, R. A., Neverova, N. & Kokkinos, I. DensePose: Dense human pose estimation in the wild. Preprint at https://doi.org/10.48550/arXiv.1802.00434 (2018).

Cao, Z., Hidalgo, G., Simon, T., Wei, S.-E. & Sheikh, Y. OpenPose: Realtime multi-person 2D pose estimation using part affinity fields. IEEE Trans. Pattern Anal. Mach. Intell. 43, 172–186 (2021).

Article PubMed Google Scholar

Fang, H.-S., Xie, S., Tai, Y.-W. & Lu, C. RMPE: Regional Multi-person Pose Estimation. Preprint at https://doi.org/10.48550/arXiv.1612.00137 (2018).

Feng, B., Powell, D. W. & Doblas, A. Marker-less motion capture system using OpenPose. in Pattern Recognition and Tracking XXXIII vol. 12101 84–93 (SPIE, 2022).

VanKeersbilck, L., Hedengren, I., Clark, M. & Hunter, I. Joint angle calculations using motion capture and deep learning pose estimation while running. Int. J. Exerc. Sci.: Conf. Proc. 14, 179 (2022).

Google Scholar

Kim, J.-K., Bae, M.-N., Lee, K., Kim, J.-C. & Hong, S. G. Explainable artificial intelligence and wearable sensor-based gait analysis to identify patients with osteopenia and sarcopenia in daily life. Biosensors 12, 167 (2022).

Article PubMed PubMed Central Google Scholar

Kim, J.-K., Bae, M.-N., Lee, K. B. & Hong, S. G. Identification of patients with sarcopenia using gait parameters based on inertial sensors. Sensors 21, 1786 (2021).

Article ADS PubMed PubMed Central Google Scholar

SMART INSOLE | PRODUCT | SALTED. https://sports.salted.ltd/en/product/smart-insole.

Dr. Logs - Google Play Store. Available online: https://play.google.com/store/apps/details?id=kr.co.deevo.android.deevo&hl=ko. (2023).

DEEVO : Data Management System (DMS). Available online : https://ai.deevo.co.kr/traces. https://ai.deevo.co.kr/traces (2023).

Google: MediaPipe GitHub Repository. Available online: https://github.com/google/mediapipe. (2023).

Nagano, H. & Begg, R. K. Shoe-insole technology for injury prevention in walking. Sensors 18, 1468 (2018).

Article ADS PubMed PubMed Central Google Scholar

Subramaniam, S., Majumder, S., Faisal, A. I. & Deen, M. J. Insole-based systems for health monitoring: Current solutions and research challenges. Sensors 22, 438 (2022).

Article ADS CAS PubMed PubMed Central Google Scholar

Almuteb, I., Hua, R. & Wang, Y. Smart insoles review (2008–2021): Applications, potentials, and future. Smart Health 25, 100301. https://doi.org/10.1016/j.smhl.2022.100301 (2022).

Article Google Scholar

Badiola-Bengoa, A. & Mendez-Zorrilla, A. A systematic review of the application of camera-based human pose estimation in the field of sport and physical exercise. Sensors 21, 5996 (2021).

Article ADS PubMed PubMed Central Google Scholar

Topham, L. K., Khan, W., Al-Jumeily, D. & Hussain, A. human body pose estimation for gait identification: A comprehensive survey of datasets and models. ACM Comput. Surv. 55, 1–42 (2022).

Article Google Scholar

Khandakar, A. et al. Design and implementation of a smart insole system to measure plantar pressure and temperature. Sensors 22, 7599 (2022).

Article ADS PubMed PubMed Central Google Scholar

Mori, K. et al. Gait characteristics of dynapenia, sarcopenia, and presarcopenia in community-dwelling Japanese older women: A cross-sectional study. Healthcare 10, 1905 (2022).

Article PubMed PubMed Central Google Scholar

Fan, Y. et al. Sarcopenia: Body composition and gait analysis. Front. Aging Neurosci. 14, 909551 (2022).

Article MathSciNet PubMed PubMed Central Google Scholar

Download references

This work was supported by the National Research Foundation of Korea (NRF) Grant funded by the Korea government (MSIT) (No.2022R1C1C1004134).

Department of Biomedical Research Institute, Inha University Hospital, Incheon, Republic of Korea

Shinjune Kim & Hyeon Su Kim

Department of Biomedical Research Institute, Gyeongsang National University Hospital, Jinju, Republic of Korea

Seongjin Park, Sangyeob Lee & Sung Hyo Seo

Department of Orthopaedic Surgery, Daejeon Eulji Medical Center, Daejeon, Republic of Korea

Yonghan Cha

Department of Orthopedic Surgery, Ajou University School of Medicine, Suwon, Republic of Korea

Jung-Taek Kim

Department of Orthopaedic Surgery, Nowon Eulji Medical Center, Seoul, Republic of Korea

Jin-Woo Kim

Department of Orthopaedic Surgery, Bumin Medical Center, Seoul, Republic of Korea

Yong-Chan Ha

Department of Orthopedic Surgery, Inha University Hospital, 27, Inhang-ro, Jung-gu, Incheon, Republic of Korea

Jun-Il Yoo

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

S.J.K., S.J.P. and J.I.Y. conceived the study and designed the experiments. S.J.P., S.Y.L., S.H.S., H.S.K., Y.H.C., J.T.K., J.W.K, and Y.C.H. collected and analyzed the data. S.J.K. and J.I.Y. wrote the manuscript with comments from all authors. All authors have read and approved the final version of the manuscript. All individuals included in this study have given their informed consent for the publication of the results.

Correspondence to Jun-Il Yoo.

The authors declare no competing interests.

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and Permissions

Kim, S., Park, S., Lee, S. et al. Assessing physical abilities of sarcopenia patients using gait analysis and smart insole for development of digital biomarker. Sci Rep 13, 10602 (2023). https://doi.org/10.1038/s41598-023-37794-7

Download citation

Received: 04 April 2023

Accepted: 28 June 2023

Published: 30 June 2023

DOI: https://doi.org/10.1038/s41598-023-37794-7

Anyone you share the following link with will be able to read this content:

Sorry, a shareable link is not currently available for this article.

Provided by the Springer Nature SharedIt content-sharing initiative

By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.

SHARE